Two compressor quotations include the same compressed air purity class. One attaches a test at the treatment outlet. The other supplies a test at the connection to a downstream production tool. The codes match, yet the evidence applies to different points in the system. A buyer paying for conditions at the tool needs a requirement and a verification plan tied to that location.
Specify the ISO 8573-1 reference, the limits for particles, water and oil, and the exact point where compliance will be verified. Add the relevant operating state and test methods. On a product page, label a component output claim with its stated conditions. A generic purifier rating or a result taken on a particular system cannot settle the condition of a different customer's piping, process or use point.
Read the three positions separately
ISO 8573-1 specifies compressed air purity classes for particles, water and oil. The class framework can be used at different points in the system. The point of use still matters to a particular claim because a measurement describes the sample taken from the stated boundary. The ISO abstract also points to other parts of the series for measurement or specification. The public abstract does not contain the entire test procedure. ISO 8573-1 public scope
The Compressed Air & Gas Institute illustrates the ordering with the notation 3:4:2. In that example, the positions refer respectively to class 3 for solid particles, class 4 for water and class 2 for oil. Record which edition, methods and reporting basis the supplier used before treating a class triplet as evidence. If the buyer specifies an additional contaminant or a special limit, write it as an additional requirement. Preserve the complete specification in the order. CAGI compressed air purity guide
| What the quotation says | Ask where it applies | Ask what establishes it |
|---|---|---|
| Air treatment unit can deliver a purity class | The stated outlet and configuration | Vendor conditions, supported flow and supporting test evidence |
| Installed system meets a class | An unambiguous connection or sampling location in the installation | Actual measurements at that point under defined operating conditions |
| Dryer provides a stated water class | Exact location for the result and its pressure conditions | Applicable water test and report basis, including pressure dew point where relevant |
| Oil class meets the order | Location and operating state matching the buyer's use | Required oil scope and applicable test methods, with sample/result evidence |
| Status is class 0 | Named contaminant and written limit agreed for that application | The relevant measurement method and documented acceptance criteria |
A filter's nominal element description provides information about a component. It does not show the particle concentrations at a production tool. Similarly, oil-free compressor construction describes part of a system. Document the proposed treatment, distribution and proof at the relevant boundary before deciding that the arrangement can meet the complete written specification.
Follow an example from outlet to machine
Imagine a fictional assembly line whose buyer calls for 3:4:2 at its air inlet under specified normal production. A configuration supplier offers equipment with a 3:4:2 test at its packaged treatment outlet. That result can be relevant to selecting equipment. The buyer still needs to determine who owns the performance of the intervening distribution and who will verify the inlet result.
In this fictional project the first downstream acceptance report returns 4:4:2 at the tool. The result belongs to the stated downstream test and operating conditions. Against the stated requirement, the particle classification needs attention. The report cannot establish whether the discrepancy is due to distribution, sampling, different test conditions or another cause. Review both underlying datasets and their methods before assigning a corrective action. The two class records should remain in the project history with their original sample points.
The commercial implication is immediate. If one quote covers treatment equipment alone and another includes installed acceptance at the tool, the buyer should compare those deliverables separately. Name the person who accepts site evidence and specify a retest responsibility if the first appropriate check fails. Avoid treating the presence of one vendor report as a substitute for the other's project scope.
State what the oil result actually includes
Oil claims need an explicit measurement boundary and a declared basis. The oil vapour measurement part of ISO 8573 discusses sampling and evaluation in support of an oil purity class. That kind of evidence should be read together with the rest of the applicable oil measurement scope. An oil vapour figure on one report is a result about the measured form under the cited method. The full purchase requirement may involve other forms and additional evidence. ISO 8573-5:2025 public scope on oil vapour measurement
Class 0 should also trigger a request for the agreed limit and verification scope. The industry guide describes a user- or supplier-specified limit more stringent than class 1. Confirm the applicable definition and agreed limit. A class 0 label alone does not tell the buyer that amount. Do not carry a claim for one contaminant across the other positions in the specification. For buyers with process-critical requirements, the quality owner should use the applicable standard and test method in the actual specification.
Compare the evidence attached to the right operating state
An acceptance sheet might specify sampling at the use connection while the named line is operating under a recorded load. A report submitted during commissioning might instead show the barely running installation or a temporary test setup. Keep that record if it helps the engineering team understand the equipment. The contractual reviewer should decide whether an additional observation is needed in the agreed operating state. Avoid adding unverified numbers to fill rows that the captured report left empty.
The same principle applies after a change. Replacing a treatment stage, adding a branch or redefining a pressure requirement can affect which earlier tests are relevant. Record each change and its scope, and let the quality owner assess which test obligations reopen. A brochure can still say a documented option is available under stated conditions. The purchaser needs an updated test plan and the corresponding result when it pays for an installation-specific condition.
Give procurement a sample record it can use
A quote request can include a small evidence sheet that follows the item through design and delivery. Record these details.
- Identify the equipment configuration, the intended use connection and the diagram or line reference that locates the sample.
- Copy the class requirement and any exceptional limits by contaminant, with the relevant standard edition.
- Describe the agreed operating conditions. Note pressure, flow, duration and any batch or condition distinctions relevant to the selected test. Site personnel should set the method and operating requirements.
- Identify which party supplies each measurement and relays the result. Bind the test report to the system or configuration and time of sampling.
- Retain the stated class and the reported result behind it. Review incomplete or conflicting measurements before accepting the corresponding class claim.
The simple sheet should say which facts will be public and which stay in controlled reports. A product page might publish the outlet scope, test service options and a clear path to a technical inquiry. It can show which configuration the claim applies to and give the buyer the terms needed for a quote comparison. Manufacturing content and export website support from Xindar
Frequently asked questions
Can a single class describe all three contaminants?
An unqualified single number is ambiguous. Ask which contaminant it describes and request the complete stated specification in the correct order for the purchase.
Can I carry an outlet result to my factory machine?
You can use it when considering the treatment equipment under its stated conditions. Get separately relevant evidence for the use connection if that is the acceptance point.
How do I compare results taken at different pressures?
Ask for the recorded measurement conditions and an agreed comparison method for the relevant characteristic. In particular, pressure dew point should be read with the reported pressure and sampling context rather than copied as a free-standing value.
Should I copy a class from another application?
Use the class required by the process, product or project owner. The fact that a classification is valid for another use does not determine the critical requirements or tests for yours.